Cable Specifications: PVC.
Cable connection direction: L-shaped.
No. of cable cores: 4.
Cable outer diameter: 5.4 mm dia.
Cable core cross-sectional area: 0.34 mm.
Cable length: 10 m.
LED: PNP.
Minimum order: 1.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
H5CX-L8D AC24DC
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Appearance: Shielded.
Sensing distance: 5 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NC.
Standard Flat Sensors in.
Many Different Variations.
Only 6 mm thick yet provides a sensing,
distance of 3 mm (TL-W3MC1).
Aluminum die-cast models also available. E3JK-R4M1 detection method: Regression reflection type with M.S.R. function,
Connection mode: lead wire,
Detection range: 5m.
Output status: ON.
Output: relay,
2 types of cost reductionSize: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Short.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Appearance: Unshielded, 17 × 17.
Sensing distance: 5 mm.
Model: Operation mode, NO.
A Wealth of Models for All Types of.
Applications.
Easy installation, high-speed pulse generator, high-speed,
rotation control, and more.
Direct mounted to metal (-N Models).
A wealth of models ideal for limit control, counting control,
and other applications (-N Models). ZX-SFW11V3 computer connected sensor function setting tool [precision monitor]Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: output (special terminal).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
H5CX-L8D AC24DC Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=H5CX-L8D AC24DC&select=5