Size: M12 (Brass); Double; Unshielded.
Sensing distance: 30 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. Multi to one function, multiple analog outputs can also be simply calculated and determined.Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 15 dia
K3HB-XAA-BCD1 AC/DC24
Protective tubing length L: 50 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Power supply voltage: 100 to 240 VAC.
Type: Temperature input.
Output relays: 1 relay.
Input types: Thermocouple or platinum resistance thermometer.
Setting units (setting range): Setting unit: 1°C or 1°F (0 to 999°C/°F).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Rotary switches simplifies temperature settings.
Universal-input support for thermocouple or platinum,
resistance thermometer sensor input.
Change the output relay between normally open and,
normally closed operation.
Alarm status identification with LED indicator.
Self-holding output.
Alarm output status can be retained even if the power,
supply is turned OFF. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
K3HB-XAA-BCD1 AC/DC24 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=K3HB-XAA-BCD1 AC/DC24&select=5