Actuator: Plunger.
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability
K3NX-VA1C-C1
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Adjustable rod lever.
Economical, Miniature Limit Switch.
Boasting Rigid Construction.
The Head, Box, and Cover mate with ridged surfaces to,
maintain strength.
A unique Head structure provides a large OT for smooth operation.
Easy-to-wire conduit opening design.
Ideal for application in printing machines, forming machines,
and light machines.
(High Switches with high sealing characteristics, such as WL or,
D4C Switches, in locations subject to oil, water, or precipitation.)
Models with grounding terminals conform to the CE marking.
Approved by CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)Action indicator: LED action indicator, mechanical indicator.
Number of contacts: 2 pole.
Operating coil voltage: AC24V.
Universal relay the best-selling MY standard mechanical indicator, can confirm the action state contact.
According to the LED action indicator light color, can identify the AC coil specifications, DC coil specifications.
Online lap tape printing operation coil specifications, the recognition is higher.
All standard specifications indicating mechanism of mechanical action (mechanical indicator).
Suitable for environmental protection RoHS.
Conforms to the UL, CSA, IEC (VDE) standardName: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Not supported.
Load power supply voltage: 400 to 480 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection. The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for150-A current detection.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used.
K3NX-VA1C-C1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=K3NX-VA1C-C1&select=5