Sensing method: Retro-reflective Sensors.
Appearance: Horizontal.
Connection method: Pre-wired.
Sensing distance: 7 m.
Functions: Timer Self Diagnosis Turbo External Diagnosis.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Name: On-site Flexible Rod Switch (with separable emergency stop switch).
Mounting method: C-clamp mounting.
Easy on-site input on-the-move
LAB2-002 DC5
Incorporation of plastic rod actuator makes the Switch easy on hands.
One-way operation:
Equipped with stopper so that operation is only possible from one direction.
Distinctive yellow used for the body.
Three different types of mounting are available.
Models with emergency-stop switch are available to suit the application. Size: 48 x 96mm.
Control output 1: relay.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: DC24V/AC24V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
LAB2-002 DC5 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=LAB2-002 DC5&select=5