Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485
LY2N-CR AC110/120
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultCase color: Light gray.
Lighting method: Chameleon; 12 VDC.
Display color symbol: R.O.G.W.
Large Rectangular-bodied Indicators.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting),
included in lineup. Size: DIN 1/16, 48 X 48 x 60mm.
Power supply voltage: AC100 ~ 240V.
Input type: thermocouple.
Alarm points: -.
Control output: relay output.
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height E5CSL:21.7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)).
From the front panel depth: 60mm.
Parameter is less, set simple.
Sampling time was reduced to 250ms. Type: open type.
Structure: bottom mounting type.
Capacity: 100W.
Output voltage: 24V.
Output current: 4.5A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)