Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
LYQ2 DC24
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Size: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Number of beams: 28.
Protective height: 560mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
LYQ2 DC24 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=LYQ2 DC24&select=5