Appearance: Unshielded, 40 × 40.
Sensing distance: 20 mm.
Output configuration: AC 2-wire.
Model: Operation mode, NC.
A Wealth of Models for All Types of.
Applications.
Easy installation, high-speed pulse generator, high-speed,
rotation control, and more.
Direct mounted to metal (-N Models).
A wealth of models ideal for limit control, counting control,
and other applications (-N Models). Actuator: Roller lever: R50
M2PJ-90A11-12EO
Item: Basic.
Pretravel (PT): 15±5°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Type: 1a1b welding terminal.
Shape: round.
Type: General load.
Action: instantaneous action (auto recovery).
With light: LED with light.
Using voltage: DC12V.
Operation Department color: red.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Lineup includes a 17.5-mm slim, compact model.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON.
Supports phase loss detection when the motor is operating.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
M2PJ-90A11-12EO Operation manual / Instructions / Catalog download link: