Short/disconnection detection: Supported.
Specifications: Outputs, NPN (- common), 32 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance
MK2P-S-VD DC12
Single-step wiring by simply inserting pole terminals. Main contacts: DPST-NO.
Auxiliary contact: None.
Number of input channels: 2 channels.
Reset mode: Auto-reset.
Input type: Inverse.
Rated voltage: 24 VAC/VDC.
Ultra Slim Safety Relay Unit.
Models of width 17.5 mm available with 2 or 3 poles. Models.
of width 22.5 mm with 3 poles also available.
Conforms to EN standards. (TÜV approval).
DIN track mounting possible. Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Alternate operation (Self-holding).
Output: SPDT.
Lighting: Incandescent lamp, 28 VDC.
Operation Unit color symbol: Enter the desired color symbol for the,
Pushbutton in @@. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
MK2P-S-VD DC12 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MK2P-S-VD DC12&select=5