C500-OD I/O Unit Transistor Output 32 pts C500-OD415CN(3G2A5-OD415CN).
DC12~48V 0.3A.I/O classification: Output.
I/O points: 8.
Internal I/O circuit common: NPN (+ common).
Rated voltage: 12 VDC, 24 VDC.
Single Cable Connection to PLC Means.
Space is Saved and Less Control Panel.
Wiring is Required.
Compact size: 182 (W) 85 (D) 68 (H) mm,
(8-point Output Block width is 102 mm).
Connects to the PC through the connecting cable,
(G79 Series) and connector, and requires only a,
snap-in operation
MM3XPN DC100/110
Surge suppressor circuit built-in.
Immediate recognition of I/O signal status using,
LED operation indicators.
G3TA I/O Solid-state relay can be mounted instead,
of G7T.
Mounts easily on a DIN track.
Approved by UL, CSA (except for G7TC-OC16-1). Sensing method: Diffuse-reflective Sensors.
Appearance: Horizontal.
Connection method: Pre-wired.
Sensing distance: 700 mm.
Functions: Timer Self Diagnosis Turbo.
Model: NPN output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Actuator: One-way roller arm lever (horizontal).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Commonly used with other Communications Units.Frequency converter input power: 3 phase AC400V.
Weight: 2.1KG.
Standard applicable line diameter: 2 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Actuator: Resin rod (rod diameter: 8).
Hermetic, Molded terminals, -140 models.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models.
MM3XPN DC100/110 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MM3XPN DC100/110&select=5