E32-A03-1 type: special beam type; wafer mapping,
Specialty: the opening angle of 1.5 degrees to adjust the optical axis after the factory; with the installation edge,
Bending radius (mm): R10.
Fiber element for meeting diversified needsSize: M30, Shielded.
Sensing distance: 15.0 mm.
Connection: Pre-wired.
Body material: Brass.
Thread length (overall length): 66 (86).
Output configuration: PNP
MS4800A-40-1560
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Type: 1a1b welding terminal.
Shape: round.
Type: small load.
Action: instantaneous action (auto recovery).
With light: LED with light.
Using voltage: DC12V.
Operation Department color: yellow.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. Actuator: One-way roller arm lever (horizontal).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
MS4800A-40-1560 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MS4800A-40-1560&select=5