I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 30K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 banks).Number of beams: 132.
Protective height: 1199mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions
MYA-LA2 DC100/110 Size: M12 (Brass); Double; Unshielded.
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. Number of beams: 104.
Protective height: 2110mm.
Previously light curtains only offered status indicators.
The three types of indicators on the F3SR-B are not only,
status indicators but enable.
the user to completely understand the status at a glance,
further enhancing usability. Appearance: Knob-type Selector Switch A22W,
LED lighting (without Voltage Reduction Unit).
Number of notches: 2 notches.
Resetting method: Automatic.
Output: SPST-NO + SPST-NC.
Operating voltage: 12 VAC/VDC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.085 A; 60 Hz, 0.070 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2600 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 39.2 Pa; 60 Hz, 53.9 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.
MYA-LA2 DC100/110 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MYA-LA2 DC100/110&select=5