E5CN, E5EN, E5AN, E5ZN, E5 / R software.
Can shorten the parameter setting, equipment adjustment, maintenance time.
Can use the computer to compile, edit and download all parameters.
Can reduce the parameter setting time.
Online monitoring function.
Up to 31 simultaneous monitoring of the data.
(but only in the same series of thermostat).
Function of parameter mask (not showing the parameters that are not used)
NS5-SQ01B-V2
(E5_N, E5_R)
With CX-Programmer at the same time start and use,
Can share the folder used by CX-Programmer.
The function of the model can be automatically retrieved only by the unit number,
Trend monitoring connection function (automatic inspection function). R87F-A_A16H-WR waterproof type AC axial flow fan (T40 * _120, wire type).
Rated voltage: 200V.
Allowable voltage range: 85 to 110% of rated voltage.
Frequency: 50/60Hz.
Rated current: 60Hz--0.098A; 50Hz--0.109A.
Rated input: 50Hz--16W:60Hz--15W.
Rated speed: 50Hz--2690r/min; 60Hz--3040r/min.
Maximum air volume: 60Hz--2.5m3/min; 50Hz--2.3m3/min.
Maximum static pressure: 50Hz--70.9Pa; 60Hz--69.6Pa.
Noise: 50Hz--43dB; 60Hz--46dB.
The axial flow fan with the best cooling is realized.
The design of low noise, high life and good environmental adaptability is considered.
Bearing with high reliability.
Specification for type 48 and metal blade with resin blade 24.
New waterproof type AC axial fan type R87F-A - A16H-WR,
(protection structure IP65).
Through UL, CSA, VDE safety standards, EN/IEC certification of the aircraft is also very rich. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
NS5-SQ01B-V2 Operation manual / Instructions / Catalog download link: