Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods
A16-24DSY
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Unit type: CS1 Basic I/O Units.
Product name: AC Input Unit.
Specifications: 100 to 120 VAC,
16 inputs 100 to 120 VDC, 16 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3,YES, @@2, YES;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,@@3,YES,
@@2, YES; CS1 Long distance Expansion Rack,
Yes; SYSMAC BUS Slave Rack, No.
Words required: (I/O bits: CIO 0000 to CIO 0319), 1 word.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. E32-T25XR type: standard type; soft (new standard),
Specialty: flat shape (small),
Shape / detection distance (mm): 160; 130; 75 (30),
Standard test object
(minimum test object) (mm) 1: 0.5 (0.005),
Fiber element for meeting diversified needsSize: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.