Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2
A165E-SY-01
External connections: 11-pin socket.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Transistor output(SPST).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Control output 1: Voltage output.
Control output 2: --.
Auxiliary output: One.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
A165E-SY-01 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A165E-SY-01&select=5