Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 45 A, 200 to 480 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents
A165W-A2MY-24D-2 (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Detection methods: on the radio type (projector + optical device).
Connection: socket type (M12).
Detection range: red light 20m.
Output mode: PNP output.
Optical projector: 2M E3Z-FTP21-L.
Optical device: 2M E3Z-FTP21-D. Sensor type and wiring: 3-wire DC PNP/2-wire DC 1-4.
Actuator wiring: Actuator wiring 3-4.
No. of ports: 4.
No. of I/O: 8.
Simple Wiring of Sensor Actuators.
Greatly reduce wiring in combination with the Smartclick XS5.
Insert the connector and turn 1/8 of a turn to lock the connectors.
Higher rated current to enable output applications.
Use previous M12 screw connectors. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
A165W-A2MY-24D-2 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A165W-A2MY-24D-2&select=5