Product name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 8; Outputs, 6;
Output type: Transistor (sourcing).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.22A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient
A22L-11A-T2
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors.
A22L-11A-T2 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=A22L-11A-T2&select=5