Structure: Case-surface mounting.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 2 Bifurcated.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption
A22L-CG-T1-20A
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also includes models that are compliant,
with the LR and VDE safety standards.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 100/110 VDC).
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC). Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
A22L-CG-T1-20A Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22L-CG-T1-20A&select=5