OMRON OMRON A22L-HG-T2-02M Price

Brand: OMRON
Country: JAPAN
Name: Pushbutton Switch
Market price: U.S.$ 40.7
(The following are the market open price not sales price!)
OMRON A22L-HG-T2-02M
Control output: relay output.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type A22L-HG-T2-02M
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). Time specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
A22L-HG-T2-02M Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=A22L-HG-T2-02M&select=5


...more relevant model market price >>>>
Related products
OMRON
Pushbutton Switch
A22L-TA-T2-02M
OMRON Pushbutton Switch A22L-TA-T2-02M
Appearance: Round/Projection type LED vo
OMRON
Pushbutton Switch
A22L-HG-T2-10A
OMRON Pushbutton Switch A22L-HG-T2-10A
Appearance: Round/Half-guard type LED vo
OMRON
Pushbutton Switch
A22L-HG-T1-02M
OMRON Pushbutton Switch A22L-HG-T1-02M
Appearance: Round/Half-guard type LED vo
OMRON
Pushbutton Switch
A22L-HG-T1-20M
OMRON Pushbutton Switch A22L-HG-T1-20M
Appearance: Round/Half-guard type LED vo
Related download