Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
A22L-HR-T1-02M Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Momentary operation (Self-resetting).
Output: SPDT.
Lighting: Incandescent lamp, 28 VDC.
Operation Unit color symbol: Enter the desired color symbol for the,
Pushbutton in @@. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. Product: 500-mm Fluororesin Tube.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Dimensions: A, 1000mm; B, 1500mm.
Model: Yellow.
Safety outputs: SPDT-NO.
Auxiliary outputs: SPDT-NC.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
New Safety Mat That Is Easy to.
Install and Maintain.
Simple connection allows multiple mats to be joined together.
A wide variety of mat sizes are available.
Obtained EN1760-1 and EN ISO13849-1 (PLd/Safety.
Category 3) certification.
Complies with North American safety standards,
including ANSI/RIA15.06-1999.
A22L-HR-T1-02M Operation manual / Instructions / Catalog download link: