Operation/resetting system: Time-limit operation/self-resetting.
Time-limit contact: 4PDT.
Time ranges: 0.04 s to 3 h.
Supply voltage: 24, 100 to 120, 200 to 230, 240 VAC (50/60 Hz);
12, 24, 48, 125, 100 to 110 VDC.
Mounting: Surface mounting (with PCB terminals).
Miniature Timer Compatible with the MY Relay.
Semi-multi power supply voltage.
Large transparent time setting knob facilitates time setting
A22L-TY-T2-02M
A flat-blade and Phillips screwdriver can also be used for time setting.
Pin configuration compatible with MY Power Relay.
LED indication for power and output statuses.
Conforms to EMC standards.
Conforms to EN 61812-1 and approved by UL and CSA. E32-DC200E type: standard type; standard,
Specialty: M3 screws (small),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsType: rectangle.
Screen mode: level 2.
Output: DPDT.
Power supply voltage: DC24V.
Contact type: standard load (AC250V, 3A; DC30V, 3A).
Operation: instantaneous action (auto reset).
Operating above color: green.
Operating under the color: green.
In the touch and the ability to protect than OMRON''s previous models have improved.
The micro volume design of 23mm is realized.
Micro design and unique combination of soft sensing.
LED has five colors (red, yellow, green, white, and blue).
Built in basic switch improves touch.
Built in basic switches in the previous model based on the OMRON to improve the protection.
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).