Appearance: Standard sound.
w/jumper direction A *2: Intermittent (high-pitched).
w/jumper direction B *2(w/o jumper): Continuous (high-pitched).
Supply voltage: 12 to 24 VAC/VDC.
Buzzer Unit Series with Cylindrical.
22-mm × 16-dia. Body.
Lineup includes standard-volume models (80 phons, constant) and,
high-volume models (70 to 95 phons, variable). Intermittent or,
continuous sound can be selected
A22RW-2MG Classification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator.
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: Yes (100 to 240 VAC only).
Control output: Contact (SPDT).
Operating mode: Up counting.
Max.counting speed: 30 cps.
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter.
Power supply freely selectable within a range of 100 to 240 VAC.
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 16 inputs, 16 outputs;
Input voltage,Input current,
Maximum switching capacity, 24VDC, 7mA,
12 to 24 VDC, 0.5 A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 2 words.
Current consumption: 5V, 0.13A; 24V, --.
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems. Number of beams: 12.
Protective height: 360mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
A22RW-2MG Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22RW-2MG&select=5