Name: Clamp Terminal Blocks.
Specifications: Inputs/Outputs;
8 inputs/8 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site
A3KA-90E1-24EW
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. No. of digits: 3.
Display color: Red.
Input method: Static.
Logic: Positive.
Display contents: Numerals and units.
A Series of Three- to Five-digit Digital.
Display Units with a Character Height of,
14 mm. Models available with either red or,
green displays.
Red or green displays with a character height of 14 mm are,
available for a variety of applications and locations.
Miniature design with a 50-mm depth.
Incorporating a connector, thus saving wiring effort.
Connecting to OMRON''s PLCs via dedicated PLC cables (sold separately).
Units and minus symbols are displayed (three- and four-digit model only).
Incorporating a zero suppression function.
The power supply can freely change between 12 and 24 VDC.
CE Marking. UL certification approval. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
A3KA-90E1-24EW Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A3KA-90E1-24EW&select=5