Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.170 A; 60 Hz, 0.150 A .
Rated input: 50 Hz, 11 W ; 60 Hz, 10 W .
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2250 r/min.
Maximum flow rate: 50 Hz, 2.0 m3/min; 60 Hz, 2.1 m3/min.
Maximum static pressure: 50 Hz, 44.1 Pa; 60 Hz, 44.1 Pa.
Noise: 50 Hz, 36 dB; 60 Hz, 38 dB
A3PJ-5776-12E
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Size: M12 (Brass); Double; Unshielded.
Sensing distance: 30 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Simple and Affordable Fiber Amplifier Units.
Reasonable price.
Use the one-key one-function feature for quick,
easy operation.
GIGA RAY for the highest level of power in this class for,
stable detection even with sensing objects with low.
reflection or large sensing objects. Control output: relay output.
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
A3PJ-5776-12E Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A3PJ-5776-12E&select=5