Type: no instantaneous contact.
Terminal configuration type: special terminal configuration.
Pin type: 8 pin.
Action mode / reset mode: time limit action / auto reset.
Output mode: contact output.
Installation method: embedded installation / front mounting.
1 units can be in 0.5 seconds to 120 seconds, select the 4 time range.
Achieved UL, CSA, NK, LR certification, in compliance with EN61812-1
A3SJ-5203
Conform to the CE mark, CCC. Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Momentary operation (Self-resetting).
Case color: Light gray.
Output: SPDT.
Lighting: Incandescent lamp; 6 VDC/VAC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Protective tubing diameter: D = 4.6.
Sleeve diameter Sleeve length: d = 8mm, l = 55mm.
tube thickness: 0.7 mm.
Lead wire length: 0.5m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Model : CV2000-CPU01-V1.
SFC / Ladder 2, 048 (with RAM62K words, the top internal link).Power supply voltage: 5 to 12 VDC.
Output configuration: Open-collector output (NPN output).
Output phases: Phases A and B.
Resolution (pulses/rotation): 100, 200, 360, 500.
Compact Encoder with External.
Diameter of 25 mm.
Incremental model.
External diameter of 25 mm.
Resolution of up to 500 ppr. Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
A3SJ-5203 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A3SJ-5203&select=5