Release key type: Special release key.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads
D2MV-01-1C1
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Appearance: Unshielded, M18.
Sensing distance: 10 mm.
Model: Operation mode, NC.
Proximity Sensor with a Long Screw Length.
Increased tightening strength. Cable protectors,
provided as a standard feature.
Increased indicator visibility.
A milled section for wrench grip on all models. Fitting materials: Stainless steel(SUS304).
Count: 1 .
Accessories: Description, Holder/bracket, Shaft (brace),
Bolt with hexagonal hole, Nut, Phillips screw, Slotted/Phillips screws;
Material, PBT (polybutylene tereph thalate), Stainless steel (SUS304),
Stainless steel (SUSXM7), Stainless steel (SUS304),
Stainless steel (SUSXM7), Stainless steel (SUS304);
Count, 1, 1, 1, 1, 1, 2.
Applicable sensor (mounting pitch on sensor side): E3Z (25.4),
E3S-R6@/R8@ (20) , E39-R3.
Page: Dimensions, 14. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
D2MV-01-1C1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D2MV-01-1C1&select=5