Supply voltage: 12 to 24 VDC.
6-digit time counter: Light gray.
DIN 48 x 24-mm Total Counter/Time Counter,
with Easy-to-read Displays and Water and,
Oil Resistance Equivalent to IP66.
High-visibility, negative transmissive LCD display with 8.5-mmhigh characters and, built-in red LED backlight at low power.
consumption.
IP66 with oil resistance and NEMA 4 protection achieved by,
unifying the front with the case and by using oil-resistant parts,
and materials
D2RV-L13
Compact (80 mm) body.
Just change a switch setting for either an NPN or PNP input.
Supports both external resetting and manual resetting.
Finger-protection terminal block cover prevents electrical shock,
and conforms to VDE0106, Part 100.
Certified for UL and CSA safety standards.
Complies with EMC standards (EN 61326) and CE Marking. Unit classification: CJ1 Special I/O Units.
Product name: ProcessInput Units,
(Isolated-type Thermocouple Input Units).
Input points: 2 inputs.
Signal range selection:
Set separately for each input.
Signal range: Thermocouple:
B, E, J, K, L, N, R, S, T, U,
WRe5-26, PLII DC voltage: ±100 mV.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 24V, 0.06A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. Actuator: Adjustable roller lever, form lock (metal lever, rubbe roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
D2RV-L13 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D2RV-L13&select=5