Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output)
D2SW-01L1H
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Product name: CJ2M CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2, 560 points/40 Units(3 ExpansionRacks max. );Programcapacity,
30K steps;Data memorycapacity, 160K words,
(DM: 32K words, EM: 32K words ×4 banks);
LD nstruction execution time, 0. 04 μs;
EtherNet/IP function: --;
Option board slot: --.
Current consumption (A): 5V, 0. 7(See note. );24V, --.
Standards: UC1, N, L, CE.
CJ2M for basic machine automation.
The CJ2M Series is ideal for packaging and general.
machine automation needs. Connectivity is assured.
thanks to the built-in USB port and the choice of.
Ethernet and RS-232C/422/485 interfaces on the CPU. Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 600W.
Output voltage: 15V.
Output current: 43A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
D2SW-01L1H Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D2SW-01L1H&select=5