Operation/resetting system: Time-limit operation/self-resetting.
Time-limit contact: DPDT(for power switching).
Time ranges: 0.04 s to 3 h.
Supply voltage: 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 100 to 110 VDC.
Mounting: Surface/DIN-track mounting (with socket).
Miniature Timer Compatible with the MY.
Relay.
UL listed when used with a Push-In Plus Terminal Block Socket.
Conforms to CSA, CE Marking, CCC and LR
D4A-A00
Black design with power supply terminals on top and contact output,
terminals on bottom.
Large transparent time setting knob facilitates time setting.
A flat-blade and Phillips screwdriver can also be used for time setting.
Semi-multi power supply voltage. Output: Time-limit contact and instantaneous contact.
Supply voltage: 100 to 240 VAC (50/60 Hz)/100 to 125 VDC;
24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-input available.
Time range: 0.05 s to 300 h.
Operating mode(See note 2): Five multi-modes: A, B,B2, E, J (Power supply start).
Output: Transistor(Photocoupler).
Supply voltage: 24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-voltage input.
Time range: 0.05 s to 300 h.
Operating mode (See note 2): Eight multi-modes: A, B, B2, C, D, E, G, J.
Multiple Operating Modes and Multiple Time.
Ranges. DIN 48 x 48-mm Multifunctional Timer.
A wide AC/DC power supply range greatly reduces the number,
of timer models kept in stock.
A wide range of applications with multiple operating modes,
eight modes for 11-pin models and five modes for 8-pin models.
Ecological design with reduced current consumption.
Easy sequence checking with instantaneous outputs for a zero set value.
Length of 75 mm or less when panel-mounted with a P3G-08,
Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC),
PNP input models available.
Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking. Number of beams: 80.
Protective height: 1600mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
D4A-A00 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D4A-A00&select=5