C500-GP Special I/O Unit GPIB Interface Unit C500-GPI01.Actuator: Sealed (Booted); Sealed plunger; AC.
Mounting: Base mounting.
Approved standards: UL CSA.
General-purpose Enclosed.
Switches with High Breaking.
Capacity and High Durability.
Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high,
breaking capacity.
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches
D4C-2402 DC models have also been added,
to the series.
Three mounting methods (side, base, and diagonal side),
and many types of actuator are available.
Terminals face the front when the cover is removed for,
easy connection.
Switches with ground terminals have CE marking.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)Appearance: Round/Projection type LED lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NO + SPST-NC.
Lighting: LED.
Operating voltage: 6 VAC/VDC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.130 A; 60 Hz, 0.100 A .
Rated input: 50 Hz, 12 W ; 60 Hz, 10 W .
Rated rotational speed: 50 Hz, 1700 r/min; 60 Hz, 2000 r/min.
Maximum flow rate: 50 Hz, 1.3 m3/min; 60 Hz, 1.5 m3/min.
Maximum static pressure: 50 Hz, 19.6 Pa; 60 Hz, 23.5 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 34 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.
D4C-2402 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D4C-2402&select=5