Appearance: Knob-type Selector Switch A22W,
LED lighting (without Voltage Reduction Unit).
Number of notches: 3 notches.
Resetting method: Manual.
Output: SPST-NC.
Operating voltage: 12 VAC/VDC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature
44526-1013 T5007-11RSSCC
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
Specifications:24 VDC, 0.5 A,
32 outputs; Sourcing.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 2 words.
Current consumption: 5V system, 0.27A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control.
44526-1013 T5007-11RSSCC Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=44526-1013 T5007-11RSSCC&select=5