Appearance: M12.
Sensing distance: 5 mm.
Connection method: M12 Connector Models.
Cable specifications: --.
Operation mode : NC .
Pin arrangement: 1: +V, 3: 0 V, 2: Control output.
Applicable connector code: D.
Model: NPN output.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals.
Wide array of variations
70152-1087 SGEY-365-0-0760 050 Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. Size: 1/8DIN 48 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Analog (Current, Voltage) Input Type.
Control method: Valve Control.
Number of alarms: 2.
Communica- tions function: RS-485.
Event input: None.
A position proportional control model for the E5EZ-PRR series.
Depth of only 78 mm.
Various temperature inputs (thermocouple, platinum resistance thermometer,
infrared temperature sensor, voltage inputs) and analog inputs (current, voltage),
Makes use of high-visibility LCD, with three lines of 4-digit display,
for simplicity.
and clarity.
3 lines of display to observe PV/ SV/ MV (valve open percentage),
clearly displaying the state of control (operations).
Event input enables multi-SP selection and run/ stop function.
Alarm delay function.
Communications function.
Able to choose closed/floating control. In floating control,
position proportional control can be performed without a potentiometer,
Equipped with a manual output function (equipped with an automatic/manual key),
CE marking and UL/CSA certification. Power ratings: 60 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 2.5 A.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
70152-1087 SGEY-365-0-0760 050 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=70152-1087 SGEY-365-0-0760 050&select=5