Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out
70156-2086 MS46SR-30-1920-Q1-1
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. External power supply: 12 VDC.
Output type: Contact and NPN transistor output.
Supply voltage: 100 to 240 VAC.
2-stage.
DIN 72 × 72 mm Multifunction Counter with a,
Bright, Easy-to-view, Negative Transmissive LCD.
Highly visible display with backlit transmissive LCD.
Selectable display color (red/green) enables checking output status at a distance.
Easy operation with a key for each digit.
Perform all basic settings with a DIP switch.
Provides a total and preset counter, batch counter, dual counter,
and tachometer (See note.).
Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and,
2-wire DC sensors.
Complies with UL, CSA, and CE marking.
Degree of protection: IP54 equivalent (front section only). Number of beams: 44.
Protective height: 1320mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
70156-2086 MS46SR-30-1920-Q1-1 Operation manual / Instructions / Catalog download link: