Appearance: Round/Projection type LED lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NO + SPST-NC.
Lighting: LED.
Operating voltage: 6 VAC/VDC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit
ZUV-L4S
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Detection mode: diffuse reflection type.
Connection mode: lead type (2 m)
Detection range: red light 1mmmm.
Output mode: NPN output. Safety instantaneous output: 2 (Semiconductor).
Safety slow-speed/stopping detection output: 2 (Semiconductor).
Auxiliary output: 4(Semiconductor).
Maximum set threshold: 10 Hz.
voltage Rated: 24 VDC.
Terminal block type: Spring-cage terminals.
Low-speed Monitoring Function Ensures.
Safety for Maintenance Work.
Motor rotation speed detected by Proximity Sensor.
Monitors and confirms that speed does not exceed the preset level.
Includes an Enabling Switch input for maintenance work.
Detailed LED indications enable easy fault diagnosis.
Safety Category 3 (EN954-1), PLd(ISO13849-1),
SIL 3 (IEC/EN 62061) certified.
ZUV-L4S Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=ZUV-L4S&select=5