Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods
E2E-X1R5E1-R-Z 5M
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). A Perfect Fit for Small Control Panels.
Coated PCBs for Better Resistance to Environment.
Connections for Easy Wiring.
Operation possible at ambient temperatures from -40 to 70°C.
DC input supported (90 to 350 VDC).
Power Boost function at 120%.
Horizontal side-by-side mounting.
Vibration resistance to 5G, and 300-VAC abnormal,
input voltage supported for 1 second.
Complies with EN/IEC 61558-2-16.
UL 508 Listing/UL 1310 Class 2 output standards *1,
ANSl/ISA 12.12.01.
Certification for 3,000 m altitude,
(UL/EN/IEC 60950-1 and EN 50178).
Lloyd’s, DNV GL *2.
Conforms to F47-0706.
Five years Warranty *3. Category: ontology; power monitoring.
Application circuit: single phase 2 wire; single phase 3 wire; three-phase 3 wire.
Supply voltage: AC100 ~ 240V (50/60Hz).
Output function: open collector output; cumulative output pulse output; alarm output.
Communication specifications: RS-485.
Memory card function: No.
Simple monitoring of the use of electricity to support energy saving countermeasures.
On behalf of the use of the mechanical equipment, the measurement of the initial voltage, current,
Cumulative quantity, invalid power, power factor, frequency.
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, and the centralized monitoring and management can be carried out in the communication network.
Wide 45mm miniaturization, simple set to the DIN guide.
E2E-X1R5E1-R-Z 5M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2E-X1R5E1-R-Z 5M&select=5