Contact configuration: Four SPST-NO relays.
Heat sink: Yes.
Built-in SSRs: G3S-201PL-PD.
Zero cross function: No.
Applicable output load: 1 A at 75 to 264 VAC (See note 1.).
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal SSR with 4 Outputs.
Easy-to-use SSR block that combines four compact G3S SSRs,
sockets, and heat sink in one unit.
Easy wiring with separate I/O terminal construction
E2E-X2MY2-Z 2M
LED operation indicator.
Special socket used for easy Relay replacement.
Mounts either on DIN track or with screws. Type: Welding / wire type, with left column.
Driving rod: long swing rod type.
Terminal specifications: with wire, the right side of the lead.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Actuator: General purpose; Roller arm lever; AC.
Mounting: Base mounting.
Approved standards: UL CSA.
General-purpose Enclosed.
Switches with High Breaking.
Capacity and High Durability.
Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high,
breaking capacity.
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added,
to the series.
Three mounting methods (side, base, and diagonal side),
and many types of actuator are available.
Terminals face the front when the cover is removed for,
easy connection.
Switches with ground terminals have CE marking.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
E2E-X2MY2-Z 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2E-X2MY2-Z 2M&select=5