Sensing method: Through beam.
Connection method (cable length): Pre-wired (5 m).
Sensing distance: 3m.
Beams: Gap, 25 mm; Qty, 5.
Sensingwidth: 100 mm.
External indicator: Possible.
Compact, Resistant to Mutual.
Interference, and Ideal for Picking a Variety of Parts.
Mounts to a parts rack and uses indicators to show parts,
picking procedures. Functions as a mistake-proofing Sensor.
Use either the built-in LED indicators or external picking indicators
E2EL-X2ME2-M3 Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 35 W.
Output voltage: 15 V.
Output current: 2.4 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Item: Sensor Head - Controller Extension Fiber Cable,
(flexible cable) (Fiber Adapter ZW-XFC provided).
Cable length: 5m.
To achieve a compact Sensor Head and high-resolution measurements,
the ZW Series uses a white light confocal principle to detect objects.
This principle is described below. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller lever, high sensitivity.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
E2EL-X2ME2-M3 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2EL-X2ME2-M3&select=5