Specification: Two contacts, vertical mounting, no rubber seal.
3-position Enabling Switch for Safer.
Robot Operation.
Clicking feel.
Conforms to U.S. standards (ANSI/RIA R15.06-1999) for.
3-position switches.
Can be mounted in two directions. E3F3-R61M detection methods: Regression reflection type,
Wire lead out type,
Type: metal appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyClassification: Standard
E2FM-X2B2 2M
Contact gap: G (0.5 mm).
Actuator: Hinge lever; High OP.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series of standard models for micro loads is available.
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
E2FM-X2B2 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2FM-X2B2 2M&select=5