Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2
E3T-SR42-S 5M
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Output: SPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Item: Sensor Head - Controller Extension Fiber Cable,
(flexible cable) (Fiber Adapter ZW-XFC provided).
Cable length: 20m.
To achieve a compact Sensor Head and high-resolution measurements,
the ZW Series uses a white light confocal principle to detect objects.
This principle is described below. Fitting materials: Iron, zinc plating.
Count: 1 .
Accessories: Description, Phillips screws M2.3 × 8,
Spring washer M2.3;
Material, Iron, zinc plating, Iron, zinc plating;
Count, 4; 4 .
Applicable sensor (mounting pitch on sensor side): E3C-S10 (7.5).
Page: Dimensions, 12. Number of beams: 40.
Protective height: 800mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
E3T-SR42-S 5M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E3T-SR42-S 5M&select=5