Type: Device Net.
The DeviceNet Communication Unit That.
Simplifies Managing Sensor Settings.
ON/OFF signals and incident light levels can be sent to the host,
PLC without any need for programming (DeviceNet communications,
slave functionality).
Threshold values and function settings can be read, written,
or taught (using the Message Communications function).
Simply connect the communication cables and slide the Amplifiers,
from the side for wire-saving
EE-SX951-R 3M
Up to 16 Sensor Amplifiers can be connected. Shape: rectangle.
Protection structure: IP40.
Action: alternate.
Operation Department color: green.
Column length 18mm, circular F8 series.
High brightness and with uniform light.
Round type easy opening.
Small and operation feel good. Type: screw terminal type, general type without cable.
Rated current; 5A AC125V.
Drive rod: sealed ball plunger type.
Terminal: screw terminal without cable.
Action indicator: no operation indicator.
Compared with D4E performance is stronger, in compliance with the requirements of high durability, high sealing.
Horizontal spring, with improved swing lever ratio of the built-in switch to provide a smooth action effect and a longer period of use.
Protection cover protects built-in switch from dust and oil pollution damage.
The plunger type combined with the solid sealing cover has longer service life.
One touch off connector wiring operation miscellaneous,
And reduce the downtime due to wiring and maintenance.
Gold Plated minimum load type is an ideal choice for electronic control.
Can provide terminal type plastic screw terminal system and terminal type plastic with operation indicator.
Certified by EN, UL, CSA and CCC (China Standard) standard.
Install the pitch and with the characteristics of D4E- - N and D4E. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: None.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
EE-SX951-R 3M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=EE-SX951-R 3M&select=5