Standard certification: No.
Insulation: photo coupler.
Zero trigger function: No.
Action indicator: No.
Applicable load of output: DC4 3A ~ 48V.
Input rated voltage: DC4 ~ 24V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type)
F3SG-4RA2030-30
A model with an action indicator to check the status of the input. (type N)Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: Yes.
Rated input voltage: DC 24V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.