Sensing method: Diffuse-reflective.
Connection method: Pre-wired M8 connector.
Sensing distance: 1 m.
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axis offset of less than ±2
F3ZN-S0495P155° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Applicable I/O Relay Terminal: G70V-SID16P-1.
Type: Input.
Internal I/O circuit common: PNP (+ common).
Rated voltage: 24 VDC.
I/O Relay Terminals with 16 Points and,
Push-In Plus terminal blocks to,
Downsize Control Panels and Save Labor.
I/O Relay Terminals with 16 points to mount G2RV Slim I/O Relays.
Push-In Plus terminal blocks are used to save wiring work in,
comparison with traditional screw terminals. (Wiring time is,
reduced by 60%* in comparison with traditional screw terminals.).
Work is reduced ever further with one-step cable connection to the PLC.
Diode provided for coil surge absorption.
Operation indicators for immediate recognition of I/O signal status.
Accepts G3RV Slim I/O SSRs.
DIN Track or screw mounting. Size: 96 × 96 mm.
Control type: Position-proportional control (1 loop).
Control mode: Single-loop position-proportional control (See note.).
Outputs(control/transfer): Relay output (1 open, 1 close).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, None; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.
F3ZN-S0495P15 Operation manual / Instructions / Catalog download link: