Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.090 A; 60 Hz, 0.075 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 1900 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 0.7 m3/min; 60 Hz, 0.8 m3/min.
Maximum static pressure: 50 Hz, 24.5 Pa; 60 Hz, 34.3 Pa.
Noise: 50 Hz, 29 dB; 60 Hz, 32 dB
G2R-1A AC100
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Timer input: PNP/NPN universal DC voltage input(4.5 to 30 VDC).
Display: 7-segment LCD with backlight.
Time range: 999999.9h ←→ 3999d23.9h(switchable); Black body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 2.2 kW (11.1 A), 200 to 220 VAC.
Monitor output: DC switching output.
New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy.
Certified for UL and CSA.
Mounts with screws or to DIN Track.
Compact design with heat sinks (3.7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator. Head material: Plastic.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+2NC.
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available.
G2R-1A AC100 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G2R-1A AC100&select=5