Function name: 3 phase 200V.
Power: 0.1KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.0KG.
Dimension (w * h) 128mm *:68.
Outline dimension (deep):109mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication
G2R-2ADC100
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller lever.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Control output: relay output.
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
G2R-2ADC100 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G2R-2ADC100&select=5