Power supply voltage: 100 to 240 VAC.
Output: Relay.
Timer function: No.
Features: Flip-flop function with two inputs/one output.
Offers High-speed Input Response of,
0.1 ms and Equipped with Built-in Timer,
High-speed response of 0.1 ms.
Ideal as a two-input Controller.
Lineup includes the S3D2-BK with flip-flop functions convenient for,
level control, the S3D2-AKD/CKD/CCD with 24-V power supply, and,
the S3D2-DK/EK with one input/output OFF-delay (two circuits),
useful for load control and lamp display,
Power source for the Sensor can be supplied up to 200 mA
G3FM-2R5SLN DC24
Ultra-slim body with 30-mm width.
Multi-function model equipped with timer functions also available. Specification: Resin, standard type.
Shaft interior (tolerance *) exterior dia: 6 dia. (Height: 8), 15 dia.
Couplings.
Coupling Materials and Characteristics.
OMRON provides two types of couplings for different.
application conditions: Resin and metal.
Select the best type for the application. Water Leak Alarm.
Flexible Setup according to Water Quality,
and Surrounding Wiring Conditions.
The operating resistance has a variable sensitivity from 0 to,
50 kΩ, so the best set values can be made according to the pre,
dicted water leakage, degree of overflow, water quality, or sur,
rounding wiring conditions.
The power supplied to the Sensing Band is 24 VAC, so opera,
tion is stable because there is no electrode deterioration from,
electrical corrosion.
A contact signal output enables monitoring from remote loca,
tions. Name: On-site Flexible Rod Switch (with separable emergency stop switch).
Mounting method: Base mounting.
Easy on-site input on-the-move.
Incorporation of plastic rod actuator makes the Switch easy on hands.
One-way operation:
Equipped with stopper so that operation is only possible from one direction.
Distinctive yellow used for the body.
Three different types of mounting are available.
Models with emergency-stop switch are available to suit the application. Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
G3FM-2R5SLN DC24 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G3FM-2R5SLN DC24&select=5