I/O classification: Temperature inputs.
I/O points: 4 inputs.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
Input specification: Platinum resistance thermometer.
Temperature Input Units for use with MULTIPLE I/O TERMINAL.
Four inputs.
Thermocouples and platinum resistance thermometer models,
are available.
Conversion time is only 250 ms for 4 inputs.
The Configurator can be used to calibrate temperatures
D2SW-P2L1H
The circuit section can be removed, so rewiring isn’t,
required during maintenance.
DIN track mounting. Output: DPDT.
Lighting: Incandescent lamp.
Operating voltage: 5 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Head material: Plastic.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+2NC.
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Size: 48 x 48mm.
Body: terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault