Total length: 610 mm.
Effective length: 740 mm.
The highest level of ionization in its class.
Sensing and variable-AC system provides fast and meticulous ionization.
Linked Ionizers cover a wide area without causing uneven ionization.
Digital ion display provides simple and reliable settings. Output: SPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white
D3V-116M-3C24
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Specification: medium capacity type.
Impact resistance: 400W.
Resistance to impact resistance: 50.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed. Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Alternate operation (Self-holding).
Output: SPDT.
Lighting: Incandescent lamp, 28 VAC/VDC.
Operation Unit color symbol: Enter the desired color symbol for the Pushbutton
n @. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. Unit: CPU Units.
Name: Standard LCD type.
No. of I/O points: 20.
LCD display: Yes.
Power supply voltage: 100 to 240 VAC.
Inputs: 12, 100 to 240 VAC.
Outputs: 8, Relays.
Buttons, calendar, and clock: Yes.
Analog input: No.
Even Broader Applications with Increased.
Functionality and Higher Precision.
Increased functionality in a compact body (70 mm wide × 90 mm high).
Easy programming is available using the LCD and operation,
buttons. (See note 1.).
This single Unit easily provides relay, timer, counter, and time,
switch functions.
Expansion is easy with Expansion I/O Units, allowing up to 44,
I/O points. (See note 2.).
Economy-type and Communications-type CPU Units have been,
added to series.
Improved Weekly Timers (See note 1.).
Increased timing accuracy with a monthly deviation of ±15 s,
max. Multiple-day operation and pulse output operation have,
been added.
Select from two power supply options:
100 to 240 VAC or 12 to 24 VDC.
D3V-116M-3C24 Operation manual / Instructions / Catalog download link: