Power supply voltage: 12 to 24 VDC.
Output configuration: NPN open collector.
Output code: Gray code.
Resolution (divisions): 256, 360, 720.
Connection method: Pre-wired Connector Model (2 m).
Rugged Rotary Encoder.
Absolute model.
External diameter of 60 mm.
Resolution of up to 1,024 (10-bit).
IP65 oil-proof protection.
Strong shaft.
Radial: 120 N, Thrust: 50 N. Size: 48 x 96mm.
Control output 1: relay output
D3V-162M-2C5
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: RS-485.
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Shape of box: Without flange.
Actuator: Roller plunger (with a 6.8-dia. roller).
Conduit: Four.
A New Monoblock Multiple Limit Switch.
Incorporating a Head Box with a Tough.
Head and Ensuring High Sealing.
Performance and a Mechanical.
Durability of 5,000,000 Operations.
Used for the sequential control of a variety of engineering.
machines and belt conveyor lines.
Built-in oil filter shuts out oil and water.
Approved by EN, IEC (Ground terminal models only.) and,
CCC (Chinese standard). Ask your OMRON representative,
for information on approved models.
Ground terminal models bear the CE mark.
D3V-162M-2C5 Operation manual / Instructions / Catalog download link: