Terminal: Screw terminal (-B).
Actuator: Panel mount cross roller plunger.
Direct Current Switch with.
Built-in Magnetic Blowout.
Incorporates a small permanent magnet in the contact.
mechanism to deflect the arc to effectively extinguish it.
Same shape and mounting procedures as the Z Basic Switches. Output: DPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2
D4NS-3DF
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. 8 pts, No-voltage contact. NPN.Type: rectangle.
Screen mode: level 2.
Using voltage: DC5V.
Operating above color: green.
Operating under the color: green.
Micro design, the length of the body is only 23mm.
LED has five colors (red, yellow, green, white, and blue).
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient. Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
Specifications: 250 VAC or 120 VDC,
2 A max. 16 outputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 1 word.
Current consumption: 5V system, 0.13A;
26 V system, 0.006per simultaneously ON outputs.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Straight/RJ45) .
Cable length: 2 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
D4NS-3DF Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D4NS-3DF&select=5