Separate Amplifier Sensor with.
Sensitivity Adjustment.
Compact design with smaller Sensor Head.
Heat-resistance model available for application between.
-10 and 200°C. Modular panel direct mounting type, easy to install and maintain the basic type.
The relay unit is modular and easy to maintain.
With LED action display function, so that the state of action at a glance.
Tropical treatment and high temperature
E2E-X5F2-M1
Stable detection can be achieved with high ambient temperature.
G4 type, with a water tank and a water supply tank level display and prevent the function of automatic water idling caused by water shortage.
Package product name: 61F-G4 base * 1, 61F-11_ unit * 5.
Purpose: General use. Actuator: Roller lever (metal lever, bearing roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Power supply: AC power supply.
Output method: Relay output.
Inputs points: 12 points.
Outputs points: 8 points.Sensing method: Through-beam (Emitter + Receiver).
Connection method: Pre-wired (2 m).
Sensing distance: 300 mm.
Operation mode: Dark-ON.
Model: PNP output.
Makes Mounting and Installation Simpler and Smoother.
Suitable for Applications in the Rechargeable Battery Industry. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Transistor output(SPST).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry.