Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved
E2E-X5ME1-M1-Z
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Highly Visible LCD Display with 2-color (Red and Green) LEDs.
Wide input range - select from two types of platinum-resistance,
thermometers and ten types of thermocouples.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Temperature input shift and temperature unit selection functions.
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate).
Finger protective cover (standard equipment) protects against,
electric shock.
Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
Recognized to conform to U.S. and Canadian requirements under,
the Component Recognition Program of UL.
CE marking. Open circuit: voltage, no voltage, DC circuit breaker.
Appearance: ADR shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 5VA below.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1a, DC; closed circuit 110V 15A 1C 1000 (L/R=0ms),
Open 110V 1A DC 1000 (L/R=25ms).
Relay control output for circuit breaker switching.
Quality: about 0.6kg.
External: Mount Searl N1.5.
High voltage grounding relay type K2GA thin,
Miniaturization, and digital type precision mounting.
Strong anti interference ability,
Stable operation in the arc grounding fault.
Can carry out fine current adjustment, easy to coordinate.
Set alarm terminal.
The adjusting part of the action current is a rotary switch mode, which is convenient for adjustment.
E2E-X5ME1-M1-Z Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2E-X5ME1-M1-Z&select=5